Katalog › Data Acquisition & Logger › imc BUSDAQflex Logger Bus Kendaraan

IMC

imc BUSDAQflex Logger Bus Kendaraan

One data logger - multiple applications

Available models include imc BUSLOGflex, imc BUSDAQflex-2S, imc BUSDAQflex-2, imc BUSDAQflex-4, imc BUSDAQflex-6, imc BUSDAQflex-8, imc BUSDAQflex-12.

imc BUSDAQflex Logger Bus Kendaraan

With the intelligent imc BUSDAQflex data logger series you have access to the usual bus systems of the automotive, railway, aircraft and machine industry. In addition to the acquisition of raw data streams and protocol channels, the live decoding of individual channels as well as complex protocols such as CCP, KWP2000, XCP, OBD2, etc. are supported. The standard basic configuration of 2 CAN nodes can be extended to 12 nodes for different field and vehicle buses for the larger device variants.

Related links

  • Data Sheets
  • Manuals

-40° to +85°C

Operating temperature with condensation allowed

UPS

Reliably protects against loss of data in the event of power failure

MIL-STD-810F

Especially robust against shock and vibration

GPS

Synchronously record position data with motion data

Supported field buses:

  • CAN
  • CAN FD
  • LIN
  • FlexRay
  • J1587
  • XCPoE
  • ARINC
  • PROFIBUS
  • PROFINET
  • Modbus
  • MVB

Supported protocols:

  • CCP
  • KWP2000
  • XCP
  • OBD2
  • UDS
  • DiagOnCan
  • TP2.0
  • GMLAN

Well networked

imc BUSDAQflex offers a wide range of networking options: cable or wireless. Via the Ethernet interface, the logger can be connected directly to your computer or a company network. For remote systems, such as a fleet testing or facility monitoring, wireless access is possible via integrated WLAN or external imc UMTS router. This allows users to remotely monitor vehicles, machines and plants, view measurement data, determine positions and customize the configuration. The data loggers of the imc BUSDAQflex series offer various possibilities of remote access:

Manual remote access

imc BUSDAQflex supports the standard protocols ftp and https for manual remote access. Users can load measured data via a standard ftp program or access the data logger via an internet browser. If the logger is equipped with the optional imc REMOTE web server, it has its own “homepage”. The design of the pages is carried out per drag & drop with finished display and control elements. In addition to the clear data presentation, interactions such as starting, stopping, triggering, etc. are also possible.

Automatic data transfer

Using the imc LINK Windows software, an automatic data transfer from imc measurement systems to your PC or a server can be realized. In addition, live information about the status of a measurement and the measurement device, as well as GPS data, can be displayed. Particularly convenient is the possibility to transfer the transferred data directly to imc FAMOS for automatic evaluation or to store it in structured form in the measurement database imc SEARCH.

Cloud connectivity

By means of imc WEBDEVICES cloud technology, data from the logger are automatically transferred to the cloud, the data integrity checked and, if desired, deleted on the logger. In addition, the cloud platform monitors characteristic values and sends notifications via SMS or e-mail when limits are exceeded. Access to the cloud is done with a standard internet browser. Users can track live status information, GPS positions and characteristic values, as well as download measurement data.

Clever functions

Sleep/Standby1 Wake-on-CAN1 Auto-start with power on Auto-backup in case of power failure Extensive intelligent trigger functions Extensive real-time analysis (imc Online FAMOS) Sending of CAN messages (with imc Online FAMOS)

1: Only with pure CAN- / LIN equipment without additional field bus interfaces such as CAN FD, FlexRay, etc.

Intelligent with imc Online FAMOS

The real-time imc Online FAMOS platform makes it possible to convert incoming measurement data directly into results and without a PC directly in the measurement device.

Freely-definable online calculations and analysis Patented data reduction Function library with over 190 functions Results in real-time Limit monitoring of any measurement channel and reaction triggering

Flexible expansion of measurement modules

The imc BUSDAQflex data logger is perfectly complemented by the imc CANSASflex series modules. The modules are directly attached to the logger by means of a click mechanism and expand its functionality with various analog and digital inputs. As a result, the user receives a particularly compact and modular measurement system.

Click-mechanism for more comfort

The imc CANSASflex series modules can be quickly connected using the click-mechanism: both mechanically and electrically. Blocks can easily be formed by simply clicking individual modules together without the use of wiring or fasteners.

Overview of device variants

Overview of device variants

Model & Varian

Perbandingan Model & Varian
ModelBus interfaces — CAN nodesBus interfaces — ExandableBus interfaces — Supported expansion modulesBus interfaces — CANBus interfaces — CAN FD
imc BUSLOGflex2noNot availableNot availableNot available
imc BUSDAQflex-2S2noNot availableNot availableNot available
imc BUSDAQflex-22noNot availableNot availableNot available
imc BUSDAQflex-42 (max. 4)yesmax. 1 moduleOptionalOptional
imc BUSDAQflex-62 (max. 6)yesmax. 2 modulesOptionalOptional
imc BUSDAQflex-82 (max. 8)yesmax. 3 modulesOptionalOptional
imc BUSDAQflex-122 (max. 12)yesmax. 5 modulesOptionalOptional

Geser tabel ke samping untuk melihat semua spesifikasi →

Spesifikasi

imc BUSLOGflex
Bus interfaces — CAN nodes2
Bus interfaces — Exandableno
Connectivity — Ethernet 100 MbitStandard
Connectivity — UMTS/LTE, 3G/4G (external)Optional
Data storage — Ring storageStandard
Data storage — Memory card slotCF-card
Software — Vector-Database (DBC)Standard
Software — imc REMOTE WebserverOptional
Software — imc STUDIOOptional
imc BUSDAQflex-2S
Bus interfaces — CAN nodes2
Bus interfaces — Exandableno
Connectivity — Ethernet 100 MbitStandard
Connectivity — UMTS/LTE, 3G/4G (external)Optional
Data storage — Ring storageStandard
Data storage — Memory card slotCF-card
Software — Vector-Database (DBC)Optional
Software — imc Online FAMOS (real-time analysis)Optional
Software — ECU-Protocols (CCP, XCP, etc.)Optional
Software — imc REMOTE WebserverOptional
Software — imc STUDIOOptional
imc BUSDAQflex-2
Bus interfaces — CAN nodes2
Bus interfaces — Exandableno
Connectivity — Ethernet 100 MbitStandard
Connectivity — UMTS/LTE, 3G/4G (external)Optional
Connectivity — GPS connectionStandard
Connectivity — Display connectionStandard
Data storage — Ring storageStandard
Data storage — Memory card slotCF-card
Software — Vector-Database (DBC)Optional
Software — imc Online FAMOS (real-time analysis)Optional
Software — ECU-Protocols (CCP, XCP, etc.)Optional
Software — imc REMOTE WebserverOptional
Software — imc STUDIOOptional
imc BUSDAQflex-4
Bus interfaces — CAN nodes2 (max. 4)
Bus interfaces — Exandableyes
Bus interfaces — Supported expansion modulesmax. 1 module
Bus interfaces — CANOptional
Bus interfaces — CAN FDOptional
Bus interfaces — LINOptional
Bus interfaces — FlexRayOptional
Bus interfaces — J1587Optional
Bus interfaces — XCPoEOptional
Bus interfaces — PROFIBUSOptional
Bus interfaces — PROFINET-IRTOptional
Bus interfaces — ModbusOptional
Bus interfaces — ARINCOptional
Bus interfaces — MVB (EMD or ESD)Optional
Bus interfaces — Kistler RoaDynOptional
Bus interfaces — APPMODOptional
Inputs & outputs — Digital inputs4
Inputs & outputs — Digital outputs4
Connectivity — Ethernet 100 MbitStandard
Connectivity — WLAN-Adapter (internal)Optional
Connectivity — UMTS/LTE, 3G/4G (external)Optional
Connectivity — GPS connectionStandard
Connectivity — Display connectionStandard
Data storage — Ring storageStandard
Data storage — Memory card slotCF-card
Software — Vector-Database (DBC)Optional
Software — imc Online FAMOS (real-time analysis)Optional
Software — ECU-Protocols (CCP, XCP, etc.)Optional
Software — imc REMOTE WebserverOptional
Software — imc STUDIOOptional
imc BUSDAQflex-6
Bus interfaces — CAN nodes2 (max. 6)
Bus interfaces — Exandableyes
Bus interfaces — Supported expansion modulesmax. 2 modules
Bus interfaces — CANOptional
Bus interfaces — CAN FDOptional
Bus interfaces — LINOptional
Bus interfaces — FlexRayOptional
Bus interfaces — J1587Optional
Bus interfaces — XCPoEOptional
Bus interfaces — PROFIBUSOptional
Bus interfaces — PROFINET-IRTOptional
Bus interfaces — ModbusOptional
Bus interfaces — ARINCOptional
Bus interfaces — MVB (EMD or ESD)Optional
Bus interfaces — Kistler RoaDynOptional
Bus interfaces — APPMODOptional
Inputs & outputs — Digital inputs4
Inputs & outputs — Digital outputs4
Connectivity — Ethernet 100 MbitStandard
Connectivity — WLAN-Adapter (internal)Optional
Connectivity — UMTS/LTE, 3G/4G (external)Optional
Connectivity — GPS connectionStandard
Connectivity — Display connectionStandard
Data storage — Ring storageStandard
Data storage — Memory card slotCF-card
Software — Vector-Database (DBC)Optional
Software — imc Online FAMOS (real-time analysis)Optional
Software — ECU-Protocols (CCP, XCP, etc.)Optional
Software — imc REMOTE WebserverOptional
Software — imc STUDIOOptional
imc BUSDAQflex-8
Bus interfaces — CAN nodes2 (max. 8)
Bus interfaces — Exandableyes
Bus interfaces — Supported expansion modulesmax. 3 modules
Bus interfaces — CANOptional
Bus interfaces — CAN FDOptional
Bus interfaces — LINOptional
Bus interfaces — FlexRayOptional
Bus interfaces — J1587Optional
Bus interfaces — XCPoEOptional
Bus interfaces — PROFIBUSOptional
Bus interfaces — PROFINET-IRTOptional
Bus interfaces — ModbusOptional
Bus interfaces — ARINCOptional
Bus interfaces — MVB (EMD or ESD)Optional
Bus interfaces — Kistler RoaDynOptional
Bus interfaces — APPMODOptional
Inputs & outputs — Digital inputs4
Inputs & outputs — Digital outputs4
Connectivity — Ethernet 100 MbitStandard
Connectivity — WLAN-Adapter (internal)Optional
Connectivity — UMTS/LTE, 3G/4G (external)Optional
Connectivity — GPS connectionStandard
Connectivity — Display connectionStandard
Data storage — Ring storageStandard
Data storage — Memory card slotCF-card
Software — Vector-Database (DBC)Optional
Software — imc Online FAMOS (real-time analysis)Optional
Software — ECU-Protocols (CCP, XCP, etc.)Optional
Software — imc REMOTE WebserverOptional
Software — imc STUDIOOptional
imc BUSDAQflex-12
Bus interfaces — CAN nodes2 (max. 12)
Bus interfaces — Exandableyes
Bus interfaces — Supported expansion modulesmax. 5 modules
Bus interfaces — CANOptional
Bus interfaces — CAN FDOptional
Bus interfaces — LINOptional
Bus interfaces — FlexRayOptional
Bus interfaces — J1587Optional
Bus interfaces — XCPoEOptional
Bus interfaces — PROFIBUSOptional
Bus interfaces — PROFINET-IRTOptional
Bus interfaces — ModbusOptional
Bus interfaces — ARINCOptional
Bus interfaces — MVB (EMD or ESD)Optional
Bus interfaces — Kistler RoaDynOptional
Bus interfaces — APPMODOptional
Inputs & outputs — Digital inputs4
Inputs & outputs — Digital outputs4
Connectivity — Ethernet 100 MbitStandard
Connectivity — WLAN-Adapter (internal)Optional
Connectivity — UMTS/LTE, 3G/4G (external)Optional
Connectivity — GPS connectionStandard
Connectivity — Display connectionStandard
Data storage — Ring storageStandard
Data storage — Memory card slotCF-card
Software — Vector-Database (DBC)Optional
Software — imc Online FAMOS (real-time analysis)Optional
Software — ECU-Protocols (CCP, XCP, etc.)Optional
Software — imc REMOTE WebserverOptional
Software — imc STUDIOOptional

Unduhan & Sumber

Datasheet5 model

Pilih model untuk membuka datasheet resmi produsen.

Butuh konsultasi teknis?

Kirim kebutuhan pengujian Anda — tim Terastek membantu menentukan konfigurasi yang sesuai.