imc CRONOSflex Sistem Akuisisi Data Modular
Modular, spatially distributable data acquisition (DAQ) system
Available models include CRFX-400 with optional CAN-Bus interface, CRFX-2000 with optional CAN-Bus interface and Multi-IO.

With the imc CRONOSflex, we offer a modular system, which gives you an unprecedented degree of flexibility in the setup of your data acquisition (DAQ) system. The system requires no rack or frame. Both base unit and the measurement modules (amplifiers or conditioners) have independent housings: by a robust “Click Mechanism”, they can easily be either connected directly to one another or alternatively spatially distributed over a standard network cable. A distance of up to 100m between individual modules is possible.
The imc CRONOSflex covers the entire frequency range of physical test and measurement requirements by providing up to 2 MSamples/s with channel rates up to 100 kSamples/s. Measurement modules are available for every common type of signal and sensor. Experience the flexibility of a modular, spatially distributable data acquisition (DAQ) system.
At a glance
- Flexible modularity through frameless expansion
- With the “Click Mechanism”, modules are physically and electronically connected
- Ideal for frequently changing measurement tasks – distributed or centrally located
- Simultaneous recording of analog, digital, and vehicle bus data
- Up to 2,000 kS/s per system and up to 100 kS/s per channel
- Supports nearly every signal and sensor type
- Synchronous acquisition from one up to thousands of channels
- Integrated real time analysis
- Ready to go configuration and operation software: imc STUDIO
- For comprehensive data analysis and reports, imc FAMOS software is ideal
imc CRONOSflex: Connectivity of the base units
With the imc CRONOSflex series, imc is offering a modular system that gives you an unprecedented level of flexibility when it comes to the compilation of your measurement system. The system doesn’t require a rack of frame, because both the base unit, as well as additional flex modules (amplifiers and conditioners), have separate, “clickable” housings.
Model & Varian
| Model | General — Aggregate sampling rate | Operating conditions — Standard operating temp. range | Operating conditions — Extended temp. range from -40 °C to +85 °C (incl. condensation) | Operating conditions — Shock vibration rating | Analog measurement modules — Measurement Connections |
|---|---|---|---|---|---|
| CRFX-400 with optional CAN-Bus interface | 400 kSps | -10°C to +55°C | ◯ | MIL-STD-810 | Modular |
| CRFX-2000 with optional CAN-Bus interface and Multi-IO | 2000 kSps | -10°C to +55°C | ◯ | MIL-STD-810 | Modular |
Geser tabel ke samping untuk melihat semua spesifikasi →
Spesifikasi
| CRFX-400 with optional CAN-Bus interface | |
|---|---|
| General — Aggregate sampling rate | 400 kSps |
| Operating conditions — Standard operating temp. range | -10°C to +55°C |
| Operating conditions — Extended temp. range from -40 °C to +85 °C (incl. condensation) | ◯ |
| Operating conditions — Shock vibration rating | MIL-STD-810 |
| Analog measurement modules — Measurement Connections | Modular |
| Connectivity — Ethernet | 100 MBit |
| Connectivity — WLAN (WiFi) IEEE 802.11.g (54 Mbit/s) | ◯ |
| Connectivity — WLAN (WiFi) IEEE 802.11.n (300 Mbit/s), dual antenna | ✕ |
| Connectivity — Wireless UMTS, 3G, 4G | ◯ |
| Connectivity — EtherCAT distributable system bus | ⬤ |
| Connectivity — GPS connection port | ⬤ |
| Connectivity — Display connection port | ⬤ |
| Connectivity — Remote controlled main switch | ⬤ |
| Connectivity — Programmable status feedback (LEDs) | ⬤ |
| Connectivity — Isolated SYNC signal | ✕ |
| Data Storage — CF card slot | ⬤ |
| Data Storage — CFast card slot | ✕ |
| Data Storage — USB 2.0 host port (external removable storage) | ✕ |
| Data Storage — Storage on PC / network drive | ⬤ |
| Data Storage — IDE hard drive (internal) | ◯ |
| Stand Alone Capabilities — PC independent complex trigger functionality | ⬤ |
| Stand Alone Capabilities — Onboard real-time data analysis (imc Online FAMOS) | ⬤ |
| Stand Alone Capabilities — Autarkic operation withour PC, self-start (timer, absolute time) | ⬤ |
| Synchronization & Clock — Master-Slave between different imc systems | ⬤ |
| Synchronization & Clock — NTP network based synchronization | ⬤ |
| Synchronization & Clock — PTP network based synchronization | ✕ |
| Synchronization & Clock — Via external GPS signal | ⬤ |
| Synchronization & Clock — Via external IRIG-B & DCF-77 signal | ⬤ |
| Synchronization & Clock — Multi-triggered data recording, multi-shot | ⬤ |
| Synchronization & Clock — Comprehensive trigger functions with pre- and post-trigger | ⬤ |
| Field Bus Extensions — CAN | ◯ |
| Field Bus Extensions — CAN FD | ◯ |
| Field Bus Extensions — LIN | ◯ |
| Field Bus Extensions — FlexRay | ◯ |
| Field Bus Extensions — XCPoE (Master or Slave) | ◯ |
| Field Bus Extensions — EtherCAT Slave | ◯ |
| Field Bus Extensions — Profinet | ◯ |
| Field Bus Extensions — Profibus | ◯ |
| Field Bus Extensions — Modbus | ◯ |
| Field Bus Extensions — ARINC | ◯ |
| Field Bus Extensions — MVB (EMD or ESD) | ◯ |
| Field Bus Extensions — IPTCom | ◯ |
| Multi-I/O Extension of Base Unit — Digital in/out, pulse counter, analog out | ◯ |
| Multi-I/O Extension of Base Unit — Signal synthesizer, PID controller | ◯ |
| Power Supply — DC input 10V to 50V | ⬤ |
| Power Supply — Isolated system-electronics | ◯ |
| Power Supply — AC/DC adapter (110 to 230VAC) | ⬤ |
| Power Supply — Supply of remote modules via Power-over EtherCAT | ⬤ |
| Power Supply — Data integrity upon power failure | ⬤ |
| Power Supply — UPS (lead gel battery) | ⬤ |
| Power Supply — UPS (extended capacity Li-Ion) | ◯ |
| CRFX-2000 with optional CAN-Bus interface and Multi-IO | |
| General — Aggregate sampling rate | 2000 kSps |
| Operating conditions — Standard operating temp. range | -10°C to +55°C |
| Operating conditions — Extended temp. range from -40 °C to +85 °C (incl. condensation) | ◯ |
| Operating conditions — Shock vibration rating | MIL-STD-810 |
| Analog measurement modules — Measurement Connections | Modular |
| Connectivity — Ethernet | 1 GBit |
| Connectivity — WLAN (WiFi) IEEE 802.11.g (54 Mbit/s) | ◯ |
| Connectivity — WLAN (WiFi) IEEE 802.11.n (300 Mbit/s), dual antenna | ◯ |
| Connectivity — Wireless UMTS, 3G, 4G | ◯ |
| Connectivity — EtherCAT distributable system bus | ⬤ |
| Connectivity — GPS connection port | ⬤ |
| Connectivity — Display connection port | ⬤ |
| Connectivity — Remote controlled main switch | ⬤ |
| Connectivity — Programmable status feedback (LEDs) | ⬤ |
| Connectivity — Isolated SYNC signal | ⬤ |
| Data Storage — CF card slot | ✕ |
| Data Storage — CFast card slot | ⬤ |
| Data Storage — USB 2.0 host port (external removable storage) | ⬤ |
| Data Storage — Storage on PC / network drive | ⬤ |
| Data Storage — IDE hard drive (internal) | ◯ |
| Stand Alone Capabilities — PC independent complex trigger functionality | ⬤ |
| Stand Alone Capabilities — Onboard real-time data analysis (imc Online FAMOS) | ⬤ |
| Stand Alone Capabilities — Autarkic operation withour PC, self-start (timer, absolute time) | ⬤ |
| Synchronization & Clock — Master-Slave between different imc systems | ⬤ |
| Synchronization & Clock — NTP network based synchronization | ⬤ |
| Synchronization & Clock — PTP network based synchronization | ⬤ |
| Synchronization & Clock — Via external GPS signal | ⬤ |
| Synchronization & Clock — Via external IRIG-B & DCF-77 signal | ⬤ |
| Synchronization & Clock — Multi-triggered data recording, multi-shot | ⬤ |
| Synchronization & Clock — Comprehensive trigger functions with pre- and post-trigger | ⬤ |
| Field Bus Extensions — CAN | ◯ |
| Field Bus Extensions — CAN FD | ◯ |
| Field Bus Extensions — LIN | ◯ |
| Field Bus Extensions — FlexRay | ◯ |
| Field Bus Extensions — XCPoE (Master or Slave) | ◯ |
| Field Bus Extensions — EtherCAT Slave | ◯ |
| Field Bus Extensions — Profinet | ◯ |
| Field Bus Extensions — Profibus | ◯ |
| Field Bus Extensions — Modbus | ◯ |
| Field Bus Extensions — ARINC | ◯ |
| Field Bus Extensions — MVB (EMD or ESD) | ◯ |
| Field Bus Extensions — IPTCom | ◯ |
| Multi-I/O Extension of Base Unit — Digital in/out, pulse counter, analog out | ◯ |
| Multi-I/O Extension of Base Unit — Signal synthesizer, PID controller | ◯ |
| Power Supply — DC input 10V to 50V | ⬤ |
| Power Supply — Isolated system-electronics | ◯ |
| Power Supply — AC/DC adapter (110 to 230VAC) | ⬤ |
| Power Supply — Supply of remote modules via Power-over EtherCAT | ⬤ |
| Power Supply — Data integrity upon power failure | ⬤ |
| Power Supply — UPS (lead gel battery) | ⬤ |
| Power Supply — UPS (extended capacity Li-Ion) | ◯ |
Unduhan & Sumber
Datasheet49 model
Pilih model untuk membuka datasheet resmi produsen.
- imcCRONOSflex-201811-Edition1-EN-WEB
- product-catalog-en
- 400-CRFX-2000
- Power-Handle
- Digital-Fieldbus
- ACC-Klemmenstecker
- ACC-DSUBM-ICP2I-BNC
- ACC-FGG-1B-307-TERMINAL
- Sonderbeschreibung-ACC-DSUBM-QB2-PH
- ACC-DSUBM-ESD
- UNI-4
- UNI2-8
- DCB2-8
- B-8
- BR2-4
- ACI-8
- LV3-8
- ISOF-8
- ISO2-8
- ISO2-8-2T-ISO2-16-2T
- AUDIO2-4
- QI-4
- ICPU2-8
- HISO-8
- HV2-2U2I
- HV2-4U
- DAC-modules
- DI-16-HV
- DIO-modules
- HRENC-4
- FRQ2-4
- Synthesizer
- NET-SWITCH-5
- ECAT-GATEWAY
- SEN-SUPPLY-4
- WFT-2
- APPMOD-Interface
- Mounting-Systems
- WLAN
- Display
- FH-FO-CONV-ECAT-ENET
- ACC-SYNC-FIBRE
- storage-media
- Sensorcable-4HV-T-1350283-1350284-1350323
- Sensorcable-4x1HV-T-1350322
- Sensorcable-HV-L1P-PT100-1350317
- Sensorcable-HV-L1P-1350318
- Sensorcable-HV-T-1350280-1350281
- HVBOX-8
Butuh konsultasi teknis?
Kirim kebutuhan pengujian Anda — tim Terastek membantu menentukan konfigurasi yang sesuai.
Produk Terkait
Referensi
https://www.imc-tm.com/products/daq-systems/imc-cronosflex/overview