CTC
CTC Armored & Braided Sensor Cables | Kabel Sensor Berpelindung
22 model Kabel armored, braided, dan hazardous area CTC untuk melengkapi instalasi pengukuran getaran, termasuk CB802 dan CB518.
Available models include CB802, CB806, CB810, CB811, CB812, CB818, CB819, CB206, CB218, CB296, CB298, CB602, CB606, CB611, CB612, CB618, CB629, CB502, CB506, CB511, CB512, CB518.

CTC Armored & Braided Sensor Cables mencakup 22 model Kabel armored, braided, dan hazardous area dari CTC: armor protected cabling, braided cabling, hazardous area approved cabling, hydraulic hose cabling. Kabel ini menghubungkan sensor getaran ke data collector atau sistem monitoring permanen.
Model & Varian
| Model | Description |
|---|---|
| CB802 | 2 Conductor, Twisted, Shielded Pair Cable, Red FEP Jacket with Stainless Steel Braided Outer Sheathing, 0.25 in. (6.4 mm) OD, 392 °F (200 °C) Max Temp |
| CB806 | 2 Conductor, Low Cost, Twisted, Shielded Pair Cable, Lightweight Red FEP Jacket with Stainless Steel Braided Outer Sheathing, 0.25 in. (6.4 mm) OD, 392 °F (200 °C) Max Temp |
| CB810 | 2 Conductor, Twisted, Shielded Pair Cable, Lightweight Black Polyurethane Jacket with Stainless Steel Braided Outer Sheathing, 0.25 in. (6.4 mm) OD, 250 °F (121 °C) Max Temp |
| CB811 | 2 Conductor, Heavy Duty Twisted, Shielded Pair Cable, Yellow FEP Jacket with Stainless Steel Braided Outer Sheathing, 0.25 in. (6.4 mm) OD, 392 °F (200 °C) Max Temp |
| CB812 | 3 Conductor, Twisted, Shielded Triad, White FEP Jacket with Stainless Steel Braided Outer Sheathing, 0.25 in. (6.4 mm) OD, 392 °F (200 °C) Max Temp |
| CB818 | 4 Conductor Twisted, Shielded Cable, Red FEP Jacket with Stainless Steel Outer Braided Sheathing, 0.25 in. (6.4 mm) OD, 392 °F (200 °C) Max Temp |
| CB819 | 4 Conductor Twisted, Shielded Cable, Orange FEP Jacket with Stainless Steel Braided Outer Sheathing, 0.25 in. (6.4 mm) OD, 392 °F (200 °C) Max Temp |
| CB206 | 2 Conductor, Low Cost, Twisted, Shielded Pair Cable, Lightweight Red FEP Jacket with Stainless Steel Outer Armor, 0.27 in. (6.9 mm) OD, 392 °F (200 °C) Max Temp |
| CB218 | 4 Conductor Shielded Cable, Red FEP Jacket with Stainless Steel Outer Armor, 0.27 in. (6.9 mm) OD, 392 °F (200 °C) Max Temp |
| CB296 | 2 Conductor, Class 1, Division 2 Approved, Twisted, Shielded Pair Cable, Lightweight Blue FEP Jacket with Stainless Steel Outer Armor, 0.27 in. (6.9 mm) OD, 392 °F (200 °C) Max Temp |
| CB298 | 4 Conductor, Class 1, Division 2 Approved, Shielded Cable, Red FEP Jacket with Stainless Steel Outer Armor, 0.27 in. (6.9 mm) OD, 392 °F (200 °C) Max Temp |
| CB602 | 2 Conductor, Twisted, Shielded Pair Cable, Red FEP Jacket with Heavy Duty Stainless Steel Outer Armor, 0.303 in. (7.7 mm) OD, 392 °F (200 °C) Max Temp |
| CB606 | 2 Conductor, Low Cost, Twisted, Shielded Pair Cable, Red FEP Jacket with Heavy Duty Stainless Steel Outer Armor, 0.303 in. (7.7 mm) OD, 392 °F (200 °C) Max Temp |
| CB611 | 2 Conductor, Twisted, Shielded Pair Cable, Yellow FEP Jacket with Heavy Duty Stainless Steel Outer Armor, 0.303 in. (7.7 mm) OD, 392 °F (200 °C) Max Temp |
| CB612 | 3 Conductor Shielded Cable, White FEP Jacket with Heavy Duty Stainless Steel Outer Armor, 0.303 in. (7.7 mm) OD, 392 °F (200 °C) Max Temp |
| CB618 | 4 Conductor, Shielded Cable, Red FEP Jacket with Heavy Duty Stainless Steel Outer Armor, 0.303 in. (7.7 mm) OD, 392 °F (200 °C) Max Temp |
| CB629 | 6 Conductor Shielded Cable, Grey FEP Jacket with Stainless Steel Outer Armor, 0.303 in. (7.7 mm) OD, 392 °F (200 °C) Max Temp |
| CB502 | 2 Conductor, Twisted, Shielded Pair Cable, Red FEP Jacket with Hydraulic Hose Outer Armor, 0.5 in. (12.7 mm) OD, 212 °F (100 °C) Max Temp |
| CB506 | Twisted, Shielded Pair Cable, Red FEP Jacket with Heavy Duty Hydraulic Hose Outer Armor, 0.5" (12.7 mm) OD, 212 °F (100 °C) Max Temp |
| CB511 | 2 Conductor, Twisted, Shielded Pair Cable, Yellow FEP Jacket with Hydraulic Hose Outer Armor, 0.5 in. (12.7 mm) OD, 212 °F (100 °C) Max Temp |
| CB512 | 3 Conductor, Shielded Cable, White FEP Jacket with Hydraulic Hose Outer Armor, 0.5 in. (12.7 mm). OD, 212 °F (100 °C) Max Temp |
| CB518 | 4 Conductor, Shielded Cable, Red FEP Jacket with Hydraulic Hose Outer Armor, 0.49 in. (12.7 mm) OD, 212 °F (100 °C) Max Temp |
Geser tabel ke samping untuk melihat semua spesifikasi →
Aplikasi
Pengujian Suara & Getaran (Sound & Vibration)
Pengujian suara & getaran (sound and vibration) mengukur respons mekanik dan akustik produk terhadap guncangan, getaran frekuensi rendah, dan kebisingan — kunci untuk NVH otomotif, reliabilitas elektronik, dan integritas struktur dirgantara.
Lihat solusi aplikasi →IIoT & Monitoring Industri — Industrial IoT & Condition Monitoring
Sistem Industrial Internet of Things (IIoT) dan condition monitoring untuk mengumpulkan, merekam, dan menganalisis data mesin, energi, suhu, getaran, arus, serta proses secara berkelanjutan.
Lihat solusi aplikasi →Penggunaan Produk