The TCP300 and TCP400 Series AC/DC current measurement family is a highly advanced current measurement system for today's current measurement needs.

Available models include TCPA300, TCPA400, TCP303, TCP305A, TCP312A, TCP404XL.

Tektronix TCPA300/TCPA400 AC/DC Current Measurement System

The TCP300 and TCP400 Series AC/DC current measurement family is a highly advanced current measurement system for today’s current measurement needs. When connected to Tektronix oscilloscopes with TEKPROBE Level II, TekConnect (w/ TCA-BNC), or TekVPI (w/ TPA-BNC) interfaces, current measurements and calculations are simple and easy.

The TCPA300 amplifier, when used with TCP312A, TCP305A, or TCP303 probes, provides a wide range of current measurement capability and spans the gap between low-level milliamp measurements to very high current levels. These three probes provide current measurement capabilities of 30 A, 50 A, and 150 A DC continuous. For even higher current levels, the TCPA400 amplifier with the TCP404XL current probe measures 500 A DC continuous and 750 A DC continuous, derated with duty cycle.

Higher-frequency performance is available with the TCP312A w/ TCPA300 providing ≥100 MHz bandwidth and a maximum current of 30 A DC.

With this new series of current measurement tools, automatic control and on-screen scaling and units is provided for users of Tektronix TDS3000, TDS500, TDS600, TDS700, TDS5000, TDS6000, and TDS7000B series oscilloscope systems (the DPO3000, MDO/MSO/DPO4000, MSO/DPO5000, and DPO7000 series oscilloscopes, the TPA-BNC adapter is required).

Even non-TEKPROBE systems can use the TCPA300/400 series to make proper current measurements by simply multiplying the measured output voltage on the oscilloscope by the TCPA300/400 series range setting.

The TCP300/TCP400 current measurement systems seamlessly integrate with your TDS series oscilloscope.

Key Features

  • Automatic scaling and units – Oscilloscope on-screen readout of magnitude and amps reduces measurement errors with no more hand calculations
  • AC/DC input coupling
  • Low insertion impedance reduces device under test loading
  • Split-core construction allows easy circuit connection
  • Status indicators provide visual operating status and notification of potential error conditions – degauss, probe open, overload, not terminated into 50 Ω, noncompatible probe type
  • Low DC drift and noise allows improved low-level current measurements
  • 3rd party safety certification

Model & Varian

Perbandingan Model & Varian
ModelMaximum CurrentMinimum CurrentBandwidthRise Time
TCPA300(Probe Dependent)—DC - 100 MHz—
TCPA400(Probe Dependent)—100 MHz—
TCP303DC: 150 AMax RMS: 150 APeak Current: 500 A5 mA15 MHz< 23 ns
TCP305ADC: 50 AMax RMS: 35.4 APeak Current: 50 A5 mA50 MHz< 7 ns
TCP312ADC: 30 AMax RMS: 21.2 APeak Current: 50 A1 mA100 MHz< 3.5 ns
TCP404XLDC: 500 AMax RMS: 500 APeak Current: 750 A1 A2 MHz< 175 ns

Geser tabel ke samping untuk melihat semua spesifikasi →

Spesifikasi

Model overview
BandwidthTCP312A w/ TCPA300: DC – 100 MHz; TCP305A w/ TCPA300: DC – 50 MHz; TCP303 w/ TCPA300: DC – 15 MHz; TCP404XL w/ TCPA400: DC – 2 MHz
Rise timeTCP312A w/ TCPA300: ≤3.5 ns; TCP305A w/ TCPA300: ≤7 ns; TCP303 w/ TCPA300: ≤23 ns; TCP404XL w/ TCPA400: ≤175 ns
DC accuracyTCP312A w/ TCPA300: ±3% of reading; TCP305A w/ TCPA300: ±3% of reading; TCP303 w/ TCPA300: ±3% of reading; TCP404XL w/ TCPA400: ±3% of reading
Accuracy, typicalTCP312A w/ TCPA300: DC: ±1% of reading; DC to 60 Hz, ≤5 A: ±1%; 60 Hz – 5 kHz, ≤5 A: ±1.5%; DC – 5 kHz, >5 A: ±1.5%; TCP305A w/ TCPA300: DC: ±1% of reading; DC to 60 Hz, ≤5 A: ±1%; 60 Hz – 5 kHz, ≤5 A: ±1.5%; DC – 5 kHz, >5 A: ±1.5%; TCP303 w/ TCPA300: DC: ±1% of reading; TCP404XL w/ TCPA400: DC: ±1% of reading
Lowest measurable current (at ±3% accuracy at DC) - Scope set to 1 mV/div and 20 MHz BW limitedTCP312A w/ TCPA300: 1 mA; TCP305A w/ TCPA300: 5 mA; TCP303 w/ TCPA300: 5 mA; TCP404XL w/ TCPA400: 1A
Maximum Amp-Second product, typical (based on amplifier range setting)TCP312A w/ TCPA300: 50 A*μS – 1 A/V; 500 A*μS – 10 A/V; TCP305A w/ TCPA300: 500 A*μS – 5 A/V; NA – 10 A/V; TCP303 w/ TCPA300: 3,000 A*μS – 5 A/V; 15,000 A*μS – 50 A/V; TCP404XL w/ TCPA400: NA – 1 A/mV
Maximum wire voltage - BareTCP312A w/ TCPA300: 150 V CAT II; TCP305A w/ TCPA300: 150 V CAT II; TCP303 w/ TCPA300: 600 V CAT I & II; TCP404XL w/ TCPA400: 600 V CAT I & II
Maximum wire voltage - InsulatedTCP312A w/ TCPA300: 300 V CAT II; TCP305A w/ TCPA300: 300 V CAT II; TCP303 w/ TCPA300: 300 V CAT III; TCP404XL w/ TCPA400: 300 V CAT III
AC-coupling low-frequency Bandwidth, typical (Low pass – 3 dB point)TCP312A w/ TCPA300
Displayed RMS noise, typical (at 20 MHz bandwidth limit)TCP312A w/ TCPA300: ≤75 μARMS; TCP305A w/ TCPA300: ≤1.25 mA RMS; TCP303 w/ TCPA300: ≤2.5 mARMS; TCP404XL w/ TCPA400: ≤250 mARMS
Signal delay (to output BNC)TCP312A w/ TCPA300: 17 ns; TCP305A w/ TCPA300: 19 ns; TCP303 w/ TCPA300: 40 ns; TCP404XL w/ TCPA400: 80 ns
Insertion impedanceTCP312A w/ TCPA300: 0.11 Ω at 1 MHz; 0.12 Ω at 10 MHz; 0.35 Ω at 50 MHz; 0.7 Ω at 100 MHz; TCP305A w/ TCPA300: 0.02 Ω at 1 MHz; 0.1 Ω at 10 MHz; 0.35 Ω at 50 MHz; TCP303 w/ TCPA300: 0.01 Ω at 1 MHz; 0.025 Ω at 5 MHz; 0.1 Ω at 15 MHz; TCP404XL w/ TCPA400: 0.1 m Ω at 10 kHz; 0.6 m Ω at 100 kHz; 8 m Ω at 1 MHz; 16 m Ω at 2 MHz
Characteristics
Maximum current ratings - High-current sensitivity - RangeTCP312A w/ TCPA300: 10 A/V; TCP305A w/ TCPA300: 10 A/V; TCP303 w/ TCPA300: 50 A/V; TCP404XL w/ TCPA400: 1 A/mV
Maximum current ratings - High-current sensitivity - DC (continuous)TCP312A w/ TCPA300: 30 A; TCP305A w/ TCPA300: 50 A; TCP303 w/ TCPA300: 150 A; TCP404XL w/ TCPA400: 500 A (750 A)
Maximum current ratings - High-current sensitivity - RMS (sinusoidal)TCP312A w/ TCPA300: 21.2 A; TCP305A w/ TCPA300: 35.4 A; TCP303 w/ TCPA300: 150 A; TCP404XL w/ TCPA400: 500 A
Maximum current ratings - High-current sensitivity - PeakTCP312A w/ TCPA300: 50 A; TCP305A w/ TCPA300: 50 A; TCP303 w/ TCPA300: 500 A; TCP404XL w/ TCPA400: 750 A
Maximum current ratings - Low-current sensitivity - RangeTCP312A w/ TCPA300: 1 A/V; TCP305A w/ TCPA300: 5 A/V; TCP303 w/ TCPA300: 5 A/V; TCP404XL w/ TCPA400: N/A
Maximum current ratings - Low-current sensitivity - DC (continuous)TCP312A w/ TCPA300: 5A; TCP305A w/ TCPA300: 25 A; TCP303 w/ TCPA300: 25 A; TCP404XL w/ TCPA400: N/A
Maximum current ratings - Low-current sensitivity - RMS (sinusoidal)TCP312A w/ TCPA300: 3.5 A; TCP305A w/ TCPA300: 17.7 A; TCP303 w/ TCPA300: 17.7 A; TCP404XL w/ TCPA400: N/A
Maximum current ratings - Low-current sensitivity - PeakTCP312A w/ TCPA300: 50 A; TCP305A w/ TCPA300: 50 A; TCP303 w/ TCPA300: 500 A; TCP404XL w/ TCPA400: N/A
Physical characteristics
Amplifiers (TCPA300/TCPA400) - Length17.3 cm (6.8 in)
Amplifiers (TCPA300/TCPA400) - Width9.14 cm (3.6 in)
Amplifiers (TCPA300/TCPA400) - Height16.7 cm (6.6 in)
Amplifiers (TCPA300/TCPA400) - Weight1.14 kg (2.5 lb)
Probes - LengthTCP305A/TCP312A: 14.99 cm (5.86 in); TCP303: 26.8 cm (10.55 in); TCP404XL: 26.8 cm (10.55 in)
Probes - WidthTCP305A/TCP312A: 1.59 cm (0.625 in); TCP303: 4.1 cm (1.60 in); TCP404XL: 4.1 cm (1.60 in)
Probes - HeightTCP305A/TCP312A: 3.2 cm (1.25 in); TCP303: 15.6 cm (6.13 in); TCP404XL: 15.6 cm (6.13 in)
Probes - WeightTCP305A/TCP312A: 0.15 kg (0.33 lb); TCP303: 0.66 kg (1.45 lb); TCP404XL: 0.88 kg (1.90 lb)
Maximum conductor sizeTCP312A: 5.0 mm (0.197 in); TCP305A: 5.0 mm (0.197 in); TCP303: 21 mm x 25 mm (0.83 x 1.0 in); TCP404XL: 21 mm x 25 mm (0.83 x 1.0 in)
Cable lengthTCP312A: 1.5 m (60 in); TCP305A: 1.5 m (60 in); TCP303: 2 m (78.7 in); TCP404XL: 8 m (315 in)
EMC environment and safety
Safety compliance - U.S. NRTL listingTCP312A/305A probe and amplifier: UL61010-2-032, UL61010-1; TCP303/404XL probe and amplifier: UL3111-2-032, UL3111-2-031; UL3111-1
Safety compliance - Canadian certificationTCP312A/305A probe and amplifier: CAN/CSA C22.2 No. 61010-1, CAN/CSA C22.2 No. 61010-2-032; TCP303/404XL probe and amplifier: CAN/CSA C22.2 No.1010.1-92
Safety compliance - European Union complianceTCP312A/305A probe and amplifier: EN61010-1, EN61010-2-032; TCP303/404XL probe and amplifier: EN61010-1/A2, EN61010-2-031, EN61010-2-032
Safety compliance - OtherTCP303/404XL probe and amplifier: IEC61010-2-032
Safety compliance - Electromagnetic compatibility, amplifiers onlyEC Council Directive 89/336/EEC, FCC Part 15, Subpart B Class A, AS/NZS 2064.1/2.
Temperature - Operating0 °C to +50 °C (32 °F to 122 °F)
Temperature - Nonoperating-40 °C to +75 °C (-40 °F to 167 °F)
Humidity - Operating5% to 95% R.H. to +30 °C (86 °F); 5% to 85% R.H. +30 °C to +50 °C (86 °F to 122 °F)
Humidity - Nonoperating5% to 95% R.H. to +30 °C (86 °F); 5% to 85% R.H. +30 °C to +75 °C (86 °F to 167 °F)
Altitude - Operating2000 m (6800 ft.) maximum
Altitude - Nonoperating12,192 m (40,000 ft.) maximum
Power requirements
Amplifiers90 V to 264 V, 47 to 440 Hz, 50 W; Maximum CAT II (auto switch)
ProbesTCP312A, TCP305A, TCP303 probes require a TCPA300 Amplifier; TCP404XL probe requires a TCPA400 Amplifier

Aplikasi

Development and analysis solutions for designers, installers, and service personnel in telecom, data comm, computer, and semiconductor power electronics environments for: - Power supplies (switching and linear)

Development and analysis solutions for designers, installers, and service personnel in telecom, data comm, computer, and semiconductor power electronics environments for: - Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)

Development and analysis solutions for designers, installers, and service personnel in telecom, data comm, computer, and semiconductor power electronics environments for: - Power inverters/converters

Development and analysis solutions for designers, installers, and service personnel in telecom, data comm, computer, and semiconductor power electronics environments for: - Electronic ballasts

Development and analysis solutions for designers, installers, and service personnel in telecom, data comm, computer, and semiconductor power electronics environments for: - Industrial/consumer electronics

Development and analysis solutions for designers, installers, and service personnel in telecom, data comm, computer, and semiconductor power electronics environments for: - Mobile communications (phone, satellite, relay stations)

Development and analysis solutions for designers, installers, and service personnel in telecom, data comm, computer, and semiconductor power electronics environments for: - Motor drives

Development and analysis solutions for designers, installers, and service personnel in telecom, data comm, computer, and semiconductor power electronics environments for: - Transportation systems (electronic vehicles, electric trains, locomotives, avionics)

Unduhan & Sumber

Butuh konsultasi teknis?

Kirim kebutuhan pengujian Anda — tim Terastek membantu menentukan konfigurasi yang sesuai.

Produk Terkait

Referensi

https://www.tek.com/en/datasheet/ac-dc-current-measurement-systems

Scroll to Top
WhatsApp