Katalog › Oscilloscope Probes › Tektronix IsoVu Isolated Current Probes | Probe Arus Terisolasi

Tektronix

Tektronix IsoVu Isolated Current Probes | Probe Arus Terisolasi

A New Level of Visibility in Current measurements.

Available models include TICP025, TICP050, TICP100.

Tektronix IsoVu Isolated Current Probes | Probe Arus Terisolasi

Make more accurate dynamic shunt‑based current measurements with IsoVu isolated current probe series current probes. High bandwidth, flexible ranges, complete galvanic isolation, and extremely low noise enable you to go beyond traditional limits—ideal for low‑noise measurements on current shunts in floating sections of power circuits.

Innovative wideband shunts, specially designed to integrate with the probe define a complete high-bandwidth, low-noise current measurement solution.

A Breakthrough in Oscilloscope Current Measurements

IsoVu isolated current probes enable measurements from DC to hundreds of MHz when paired with high-performance shunts or CVRs. Choose from three models to fit your application and budget.Complete RF isolation between the probe tip and the scope eliminates ground loops and dramatically reduces common mode noise.Low attenuation, 50 Ω input impedance, and shielded tips ensure low noise contribution. Watch the overview video to learn more
  • Three bandwidths: 250 MHz, 500 MHz, 1 GHz
  • Up to 90 dB CMRR @ 1 MHz
  • Noise contribution < 4.7 nV/√Hz (

Minimize Connection Hassles

Flexible probe tips and cables minimize connection hassles while limiting noise. They bend easily to reduce strain for making reliable connections to your DUT. Tektronix wideband shunts use standard square pins for high performance with low cost per test point.
  • Probe tips terminate in shielded, high-bandwidth MMCX connectors; compatible with off-the-shelf SMA or BNC adapters
  • Easily connect to 25 mil square pins for on-board shunts and test points
  • Scopes automatically recognize tip attenuations and shunt values
  • Included bipod and tripod adapters provide stability

Seamless Integration with 4, 5 and 6 Series MSO Oscilloscopes

4, 5 and 6 Series MSO oscilloscopes are known for their advanced power analysis capabilities. IsoVu current probes are designed to work seamlessly with these instruments. The TekVPITM probe interface powers the probe, and automatically detects the probe and tip, allowing you to adjust probe parameters from the scope user interface. This also enables test automation using the oscilloscopes’ programming commands.

Perform Validation Testing Across Extreme Temperature Ranges

These optional extreme temperature tips enable IsoVu Isolated Current Probes to perform measurements across a wide temperature range from -40°C to +125°C. Featuring six foot reach (1.8 m), these tips provide convenient MMCX connectivity between a DUT inside a temperature chamber and the current probe located outside the chamber. These tips are available in 1X, 10X, and 100X attenuation options and offer bandwidth performance up to 700 MHz.

Model & Varian

Perbandingan Model & Varian
ModelBandwidthDifferential VoltageCommon Mode VoltageCommon Mode Rejection Ratio
TICP025250 MHz±0.5 V (1x Tip) ±5 V (10x Tip) ±50 V (100x Tip)1.8 kV Pollution degree 1 1000 V CAT II140 dB at DC90 dB at 1 MHz (1x Tip)
TICP050500 MHz±0.5 V (1x Tip) ±5 V (10x Tip) ±50 V (100x Tip)1.8 kV Pollution degree 1 1000 V CAT II140 dB at DC90 dB at 1 MHz (1x Tip)
TICP1001 GHz±0.5 V (1x Tip) ±5 V (10x Tip) ±50 V (100x Tip)1.8 kV Pollution degree 1 1000 V CAT II140 dB at DC90 dB at 1 MHz (1x Tip)

Geser tabel ke samping untuk melihat semua spesifikasi →

Spesifikasi

Model & SeriesIsoVu™ Isolated Current Probes
Bandwidth250 MHz to 1 GHz (model-dependent)
Differential Voltage± 0.5 V to ± 50 V (model-dependent)
Common Mode Voltage1000 V
Common Mode Rejection Ratio140 dB at DC90 dB at 1 MHz (1x Tip)

Aplikasi

Gain New Insights into SiC and GaN Power Converters | Analisis Konverter Daya SiC dan GaN

For measuring fast-changing currents in wide bandgap switching devices, shunt probes can deliver more bandwidth than clamp-on probes. IsoVu isolation eliminates ground loops, enables measurements on high-voltage circuits, and provides extremely high CMRR. This makes IsoVu isolated current probes ideal…

  • 250 MHz, 500 MHz, or 1 GHz bandwidth
  • 1800 VRMS Common mode voltage
  • Up to 90 dB CMRR @ 1 MHz
  • 1000 V CAT II Safety rating

Measure Current Draw in Nanoseconds and Microamps in Low Power Designs | Pengukuran Arus dalam Nanodetik dan Mikroampere pada Desain Daya Rendah

Accurately measuring low-level, dynamic currents can be critical for optimizing power management in IoT and mobile devices. With IsoVu isolated current probes and wideband shunts, you’ll be able to see current consumption during specific system activities, like transitions from sleep…

  • Probe bandwidth up to 1 GHz
  • Noise contribution < 4.7 nV/√Hz (<150 µV at 1 GHz)
  • Easily measure 12, 24 or 48 V rails, or higher
  • 250 MHz bandwidth shunts: 5 mΩ ,50 mΩ, 500 mΩ, or 5 Ω

Unduhan & Sumber