Tektronix
Tektronix IsoVu Isolated Voltage Probes | Probe Tegangan Terisolasi
Discover fast, accurate differential measurements with IsoVu™ Probe Technology. Eliminate common mode interference and get unmatched performance with IsoVu Gen 2 probes.
Available models include TIVP02, TIVP02L, TIVP05, TIVP05L, TIVP1, TIVP1L.

Uncover the fast, floating signals that your non-isolated probes are hiding. IsoVu Probe Technology virtually eliminates common mode interference using optical isolation. This delivers accurate differential measurements on reference voltages slewing ±60kV at 100V/ns or faster. And with our IsoVu Generation 2 design, you get all the benefits of IsoVu technology at 1/5 of the size.
With versatile MMCX connectors and an unmatched combination of bandwidth, dynamic range, and common mode rejection, IsoVu Gen 2 probes are setting new standards for isolated probe technology.
Less Common Mode Noise, More Detail
- Floating measurements in power supplies
- Measuring current through shunt resistors
- Debugging ESD and EMI susceptibility problems
- Breaking ground loops
High Differential Voltage at a Range of Bandwidths
Innovative Technology in a Space-Saving Design
- Better DC gain accuracy
- Improved step response
- More built-in ranges
High Performance with Convenient Connections
Model & Varian
| Model | Bandwidth | Differential Voltage | Common Mode Voltage | Common Mode Rejection Ratio | Fiber Cable Length |
|---|---|---|---|---|---|
| TIVP02 | 200 MHz | ±2500 V | ±60 kV | DC: 160dB; 100 MHz: 100 dB; 200 MHz: 100 dB | 2 meters |
| TIVP02L | 200 MHz | ±2500 V | ±60 kV | DC: 160dB; 100 MHz: 100 dB; 200 MHz: 100 dB | 10 meters |
| TIVP05 | 500 MHz | ±2500 V | ±60 kV | DC: 160dB; 100 MHz: 100 dB; 200 MHz: 100 dB | 2 meters |
| TIVP05L | 500 MHz | ±2500 V | ±60 kV | DC: 160dB; 100 MHz: 100 dB; 200 MHz: 100 dB | 10 meters |
| TIVP1 | 1 GHz | ±2500 V | ±60 kV | DC: 160dB; 100 MHz: 100 dB; 200 MHz: 100 dB | 2 meters |
| TIVP1L | 1 GHz | ±2500 V | ±60 kV | DC: 160dB; 100 MHz: 100 dB; 200 MHz: 100 dB | 10 meters |
Geser tabel ke samping untuk melihat semua spesifikasi →
Spesifikasi
| Model & Series | IsoVu™ Isolated Voltage Probes |
|---|---|
| Bandwidth | 200 MHz to 1 GHz (model-dependent) |
| Differential Voltage | ± 2500 V |
| Common Mode Voltage | ±60 kV |
| Common Mode Rejection Ratio | DC: 160 dB; 100 MHz: 100 dB; 200 MHz: 100 dB |
| Fiber Cable Length | Model-dependent — see Model & Varian |
Aplikasi
Floating Measurements on Power Supplies | Pengukuran Mengambang pada Catu Daya
Making high-side measurements in half-bridge power converters is challenging because the source or collector to which the measurements are referenced is slewing rapidly up and down. Wide bandgap devices like SiC and GaN FETs are even harder to measure because…
Measuring Current Through Shunt Resistors | Pengukuran Arus melalui Resistor Shunt
Measuring the differential voltage across a shunt resistor should be an easy way to get accurate current measurements. But due to the common mode voltages involved, it can be surprisingly challenging. IsoVu, with its high common mode voltage rating and…
Debugging ESD Issues | Debugging Masalah ESD
Going beyond functional testing to troubleshoot the root cause of ESD failures can be frustrating. When using conventional electrical probes, the ESD discharge couples into the probe and propagates down the cable to the oscilloscope, even if the scope is…