KatalogSMU & SourceMeterKeithley 4200A-SCS — Parameter Analyzer
Keithley 4200A-SCS — Parameter Analyzer
Keithley SMU & SourceMeter

Keithley 4200A-SCS — Parameter Analyzer

Keithley 4200A-SCS Parameter Analyzer · SMU & SourceMeter
Spesifikasi Utama
  • DC Current-Voltage (I-V) Range10 aA - 1A 0.2 µV - 210 V
  • Capacitance-Voltage (C-V) Range1 kHz - 10 MHz ± 30V DC bias
  • Pulsed I-V Range±40 V (80 V p-p), ±800 mA 200 MSa/sec, 5 ns sampling rate

Gambaran Umum

Parameter Analyzer 4200A-SCS untuk karakterisasi semikonduktor, material, dan analisis kegagalan (failure analysis) dengan kumpulan pengukuran lengkap dan GUI berbasis proyek.

Spesifikasi

DC Current-Voltage (I-V) Range10 aA - 1A 0.2 µV - 210 V
Capacitance-Voltage (C-V) Range1 kHz - 10 MHz ± 30V DC bias
Pulsed I-V Range±40 V (80 V p-p), ±800 mA 200 MSa/sec, 5 ns sampling rate

Aplikasi

Keithley Keithley 4200A-SCS Parameter Analyzer — aplikasi utama dari pabrikan:

Accurate C-V Characterization Measure single-digit femtofarads with Keithley's newest capacitance-voltage unit (CVU), the 4215-CVU. By integrating a 1 V AC source into Keithley's industry-leading CVU architecture, the 4215-CVU offers low-noise capacitance measurements at frequencies from 1 kHz to 10 MHz.
  • First C-V meter in its class capable of driving a 1 V AC source voltage
  • 1 kHz frequency resolution from 1 kHz to 10 MHz
  • Measure capacitance, conductance, and admittance
  • Measure on up to four channels with the 4200A-CVIV Multiswitch
Biosensor Characterization Biosensors or bioFETs convert biological response to an analyte into an electrical signal. The Clarius Software that is integrated into the 4200A-SCS includes a project for testing bioFETs. Use it as a starting point to characterize transfer and output characteristics…
Femtofarad Capacitance Measurements Measure sub-femtofarad capacitances with the 4215-CVU module. By driving 1 V AC, the 4215-CVU can achieve a noise level as low as six attofarads when measuring a 1 fF capacitor. This is just one of dozens of applications included with…
  • Built-in femtofarad measurement capability
  • 10,000 frequency steps from 1kHz to 10MHz
  • Customize any test to any device using user libraries
Semiconductor and NVM Reliability Put your new technologies to the test with thorough pulsed I-V characterization. The 4200A-SCS comes with support and ready-to-run tests for the latest in NVRAM technologies from floating gate flash to ReRAM and FeRAM. Dual sourcing and measuring capabilities in…
Resistivity of Materials Use a 4200A-SCS with integrated SMUs to easily measure resistivity using a four-point collinear probe or van der Pauw method. Included tests perform repetitive van der Pauw calculations automatically, saving you valuable research time. A maximum current resolution of 10aA…
MOSFET Characterization The 4200A-SCS can hold all the instruments necessary for full characterization of MOS devices through component or on-wafer testing. Included tests and projects solve for oxide thickness of a MOSCap, threshold voltages, doping concentration, mobile ion concentration, and more. All…

Produk Terkait

Butuh Penawaran?

Kirim kebutuhan Anda — tim kami merespons cepat pada jam kerja (Senin–Jumat, 08.30–17.30 WIB).

Scroll to Top