PCB Piezotronics
PCB Piezotronics Cryogenic Icp Pressure Sensor Series
Cryogenic ICP® pressure sensor, 100 psi, 50 mV/psi, 3/8-24 mtg thd, safety wire holes. Operating temperature range of -400 to +212F (-240 to + 100C)
Available models include 102C10, 102C11, 102C13, 102C14, 102M295, 102M305.

Cryogenic ICP® pressure sensor, 100 psi, 50 mV/psi, 3/8-24 mtg thd, safety wire holes. Operating temperature range of -400 to +212F (-240 to + 100C)
This series groups the official PCB Piezotronics variants listed below. Differences such as frequency, configuration, connector, range, or regional option are shown in the table.
Key Features
Cryogenic ICP® pressure sensor, 100 psi, 50 mV/psi, 3/8-24 mtg thd, safety wire holes. Operating temperature range of -400 to +212F (-240 to + 100C)
- Measurement Range: 100 psi (690 kPa)
- Sensitivity: (±15%)50 mV/psi (7.25 mV/kPa)
- Low Frequency Response: (-5%)0.50 Hz
- Resonant Frequency: >=250 kHz (>=250 kHz)
- Electrical Connector: 10-32 Coaxial Jack
- Weight: 0.388 oz (11.00 gm)
- * *
Model & Varian
| Model | Official Variant Description | Measurement Range (for ±5V output) | Maximum Pressure (Total) | Resolution | Resonant Frequency | Low Frequency Response (-5 %) | Non-Linearity | Acceleration Sensitivity | Temperature Range (Operating) |
|---|---|---|---|---|---|---|---|---|---|
| 102C10 | 102C10 Cryogenic Icp Pressure Sensor | 100 psi / 690 kPa | 15 kpsi / 103425 kPa / [3] | 2 mpsi / 0.014 kPa / [2] | ≥250 kHz | 0.50 Hz | ≤1.0 % FS / [1] | 0.002 psi/g / 0.0014 kPa/(m/s²) / [2] | -400 to +212 °F / -240 to +100 °C |
| 102C11 | 102C11 Cryogenic Icp Pressure Sensor | 1 kpsi / 6895 kPa | 15 kpsi / 103425 kPa / [3] | 20 mpsi / 0.138 kPa / [2] | ≥250 kHz | 0.25 Hz | ≤1.0 % FS / [1] | 0.002 psi/g / 0.0014 kPa/(m/s²) / [2] | -400 to +212 °F / -240 to +100 °C |
| 102C13 | 102C13 Cryogenic Icp Pressure Sensor | 10 kpsi / 68950 kPa | 15 kpsi / 103425 kPa | 200 mpsi / 1.4 kPa / [2] | ≥250 kHz | 0.1 Hz | <1 % FS / [1] | 0.002 psi/g / 0.0014 kPa/(m/s²) / [2] | -400 to +212 °F / -240 to +100 °C |
| 102C14 | 102C14 Cryogenic Icp Pressure Sensor | 5 kpsi / 34475 kPa | 15 kpsi / 103425 kPa | 100 mpsi / 0.690 kPa / [2] | ≥250 kHz | 0.25 Hz | ≤1.0 % FS / [1] | 0.002 psi/g / 0.0014 kPa/(m/s²) / [2] | -400 to +212 °F / -240 to +100 °C |
| 102M295 | 102M295 Cryogenic Icp Pressure Sensor | 3500 psi / 24133 kPa / [3] | 10000 psi / 68950 kPa | 0.02 psi / 0.14 kPa / [2] | ≥250 kHz | 0.5 Hz | ≤1.0 % FS / [1] | 0.002 psi/g / 0.0014 kPa/(m/s²) / [2] | -400 to +212 °F / -240 to +100 °C |
| 102M305 | 102M305 Cryogenic Icp® Pressure Sensor | 145 psi / 1000 kPa | 2900 psi / 20000 kPa / [3] | 1 mpsi / .007 kPa / [2] | ≥250 kHz | 0.25 Hz | ≤1.0 % FS / [1] | 0.002 psi/g / 0.0014 kPa/(m/s²) / [2] | -400 to +212 °F / -240 to +100 °C |
Geser tabel ke samping untuk melihat semua spesifikasi →
Spesifikasi
| Measurement Range (for ±5V output) | 100 psi / 690 kPa |
|---|---|
| Useful Overrange (for ± 10V output) | 200 psi / 1380 kPa / [4] |
| Sensitivity (±15 %) | 50 mV/psi / 7.25 mV/kPa |
| Maximum Pressure (step) | 1000 psi / 6900 kPa |
| Maximum Pressure (Total) | 15 kpsi / 103425 kPa / [3] |
| Resolution | 2 mpsi / 0.014 kPa / [2] |
| Resonant Frequency | ≥250 kHz |
| Rise Time | ≤2.0 µ sec |
| Low Frequency Response (-5 %) | 0.50 Hz |
| Non-Linearity | ≤1.0 % FS / [1] |
| Acceleration Sensitivity | 0.002 psi/g / 0.0014 kPa/(m/s²) / [2] |
| Temperature Range (Operating) | -400 to +212 °F / -240 to +100 °C |
| Temperature Coefficient of Sensitivity | ≤0.06 %/°F / ≤0.108 %/°C |
| Maximum Vibration | 2000 g pk / 19600 m/s² pk |
| Maximum Shock | 20000 g pk / 196000 m/s² pk |
| Output Polarity (Positive Pressure) | Positive |
Unduhan & Sumber