Siglent
Siglent SAP Series Active Probe 1/2.5/5/8 GHz | Probe Aktif
SIGLENT’s active single-ended/differential probe has the characteristics of high bandwidth, low noise and high input impedance.
Available models include SAP1000, SAP2500, SAP2500D, SAP5000D, SAP8000D.

SIGLENT’s active single-ended/differential probe has the characteristics of high bandwidth, low noise and high input impedance. It is powered by SAPBus interface without external power supply, and is suitable for high-speed signal, power supply integrity measurement and differential bus analysis.
High-Frequency Differential Active Probe
SIGLENT‘s active differential probe has the advantages of high bandwidth, low noise and high input impedance. In differential signal measurement, high input impedance can minimize the influence of the probe on the circuit under test and ensure the authenticity of signal measurement; Low noise performance helps to present the characteristics of differential signals more clearly. It has excellent common-mode rejection ability, can effectively suppress common-mode noise interference, accurately extract differential signals, and is widely used in the measurement of high-speed differential signals.
Single-Ended Active Probe
SIGLENT‘s active single-ended probe has the characteristics of high bandwidth, low noise and high input impedance. Its high input impedance can effectively reduce the load influence on the circuit under test and ensure the accuracy of measurement; Low noise makes the measurement results more pure and stable, and avoids interference. It can quickly and accurately capture the change details of high-speed single-ended signals, and is suitable for the measurement of single-ended signals in high-speed digital circuits, as well as the single-ended signal measurement scenes of microprocessors, FPGA and other devices.
Test scenario full coverage
A variety of probe accessories have brought many conveniences and advantages to users, greatly enhancing the probe function, improving the efficiency and accuracy of users in use, supporting more application scenarios and helping users to make better use of probes for efficient and accurate measurement. A variety of probe accessories have brought many conveniences and advantages to users, greatly enhanced the probe function, improved the efficiency and accuracy of users in use, supported more application scenarios and helped users to make better use of probes for efficient and accurate measurement. * High-Frequency Differential Active Probe * Single-Ended Active Probe * Test scenario full coverage
Model & Varian
| Model | Probe Type | Bandwidth | Attenuation Rate | Dynamic Range | Offset Range | Interface |
|---|---|---|---|---|---|---|
| SAP1000 | single end | 1 GHz | 10X | ±8 V | ±12 V | SAPBus |
| SAP2500 | single end | 2.5 GHz | 10X | ±8 V | ±12 V | SAPBus |
| SAP2500D | difference | 2.5 GHz | 10X | ±4 V | ±8 V | SAPBus |
| SAP5000D | difference | 5 GHz | 10X | ±2.5 V | ±12 V | SAPBus |
| SAP8000D | difference | 8 GHz | 10X | ±2.5 V | ±12 V | SAPBus |
Geser tabel ke samping untuk melihat semua spesifikasi →
Spesifikasi
| Model Variants | SAP1000, SAP2500, SAP2500D, SAP5000D, SAP8000D |
|---|---|
| Probe Type | single end; difference |
| Bandwidth | 1 GHz; 2.5 GHz; 5 GHz; 8 GHz |
| Attenuation Rate | 10X |
| Dynamic Range | ±8 V; ±4 V; ±2.5 V |
| Offset Range | ±12 V; ±8 V |
| Interface | SAPBus |
Unduhan & Sumber
Butuh konsultasi teknis?